5
-
20
*The
setting
range
for
acceleration/deceleration
times
will
depends
on
the
setting
for
C1-10.
When
C1-10
is
set
to
0,
the
setting
range
for
acceleration/decel-
eration
times
becomes
0.00
to
600.00
seconds.
C1-09
Decelera-
tion
Stop
Time
The
deceleration
time
when
the
multi-function
input
“Deceleration
stop”
is
set
to
ON.
This
function
can
be
used
a
stopped
method
when
a
fault
has
been
detected.
0.0
to
6000.0
*
10.0
s No A A A 208H 6-18
Fast
Stop
Time
C1-10
Accel/decel
time
setting
unit
0: 0.01-second
units
1: 0.1-second
units
0
or
1 1 No A A A 209H 6-19
Acc/Dec
Units
C1-11
Accel/decel
time
switch-
ing
fre-
quency
Sets
the
frequency
for
auto-
matic
acceleration/decelera-
tion
switching.
Below
set
frequency:
Accel/
decel
time
4
Above
set
frequency:
Accel/
decel
time
1
The
multi-function
input
“accel/decel
time
1”
or
“accel/decel
time
2”
take
pri-
ority.
0.0
to
400.0
0.0
Hz No A A A 20AH 6-19
Acc/Dec
SW
Freq
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals