Page #147 background image
P
arameter Tables
5
-
2
1
nS-curve
Acceleration/Deceleration:
C2
Parameters
for
S-curve
characteristics
are
shown
in
the
following
table.
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register
Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
C2-01
S-curve
character-
istic
time
at
acceler-
ation
start
All
sections
of
the
S-curve
charac-
teristic
time
are
set
in
seconds.
When
the
S-curve
characteristic
time
is
set,
the
accel/decel
times
will
increase
by
only
half
of
the
S-curve
characteristic
times
at
start
and
end.
0.00
to
2.50
0.20
s No A A A 20BH 6-20
SCrv
Acc
@
Start
C2-02
S-curve
character-
istic
time
at
acceler-
ation
end
0.00
to
2.50
0.20
s No A A A 20CH 6-20
SCrv
Acc
@
End
C2-03
S-curve
character-
istic
time
at
deceler-
ation
start
0.00
to
2.50
0.20
s No A A A 20DH 6-20
SCrv
Dec
@
Start
C2-04
S-curve
character-
istic
time
at
deceler-
ation
end
0.00
to
2.50
0.00
sNoAAA20EH6-20
SCrv
Dec
@
End
R
un command
Output frequency
Time
ON
OFF
C2-02 C2-03
C2-04C2-01

Table of Contents