P
arameter Tables
5
-
3
7
nMotor
2
Setup:
E4
Parameters
for
motor
2
are
shown
in
the
following
table.
*1.The
factory
setting
depends
upon
the
Inverter
capacity.
The
value
for
a
200-V
class
Inverter
of
0.4
kW
is
given.
*2.The
setting
range
is
10%
to
200%
of
the
Inverter's
rated
output
current.
The
values
for
a
200-V
class
Inverter
of
0.4
kW
is
given.
*3.If
a
multi-function
input
is
set
for
motor
2
(H1-
@@
=
16),
the
factory
setting
will
depend
upon
the
Inverter
capacity.
The
value
for
a
200-V
class
Inverter
of
0.4
kW
is
given.
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
E4-01
Motor
2
rated
cur-
rent
Sets
the
motor
rated
current
in
1
A
units.
These
set
values
will
become
the
reference
values
for
motor
protection,
torque
lim-
its
and
torque
control.
This
parameter
is
automati-
cally
set
during
autotuning.
0.32
to
6.40
*2
1.90
A
*1
No A A A 321H 6-47
Motor
Rated
FLA
E4-02
Motor
2
rated
slip
Sets
the
motor
rated
slip
in
Hz
units.
These
set
values
will
become
the
reference
values
for
slip
compensation.
This
parameter
is
automati-
cally
set
during
autotuning.
0.00
to
20.00
2.90
Hz
*1
No AAA322H -
Motor
Rated
Slip
E4-03
Motor
2
no-
load
current
Sets
the
motor
no-load
cur-
rent
in
1
A
units.
This
parameter
is
automati-
cally
set
during
autotuning.
0.00
to
1.89
*3
1.20
A
*1
No AAA323H -
No-Load
Current
E4-04
Motor
2
number
of
poles
(num-
ber
of
poles)
Sets
the
number
of
motor
poles.
This
parameter
is
automati-
cally
set
during
autotuning.
2
to
48 4
poles No No A No 324H -
Number
of
Poles
E4-05
Motor
2
line-to-line
resistance
Sets
the
motor
phase-to-
phase
resistance
in
units.
This
parameter
is
automati-
cally
set
during
autotuning.
0.000
to
65.000
9.842
*1
No AAA325H -
Term
Resis-
tance
E4-06
Motor
2
leak
induc-
tance
Sets
the
voltage
drop
due
to
motor
leakage
inductance
as
a
percentage
of
the
motor
rated
voltage.
This
parameter
is
automati-
cally
set
during
autotuning.
0.0
to
40.0
18.2%
*1
No No No A 326H -
Leak
Induc-
tance
E4-07
Motor
2
rated
capac-
ity
Set
the
rated
output
of
the
motor
in
units
of
0.01
kW.
This
parameter
is
automati-
cally
set
during
autotuning.
0.40
to
650.00
0.40
*1
No AAA327H -
Mtr
Rated
Power

Table of Contents