1
-
6
Table
1.4
Differences
in
Software
(Continued)
Name Parameter
Number Asia
Europe
suffixed
-E
LCD
brightness
adjustment
o1-05 Cannot
change.
Setting
Range:
0
to
5
Adjusts
the
brightness
in
five
steps.
Operation
selection
when
Digital
Opera-
tor
is
disconnected
o2-06
Factory
setting
0
(Disabled)
Factory
setting
0
(Disabled)
Cumulative
opera-
tion
time
selection
o2-08
Factory
setting
=
0
(Cumulative
time
when
the
Inverter
power
is
ON)
Factory
setting
=
1
(Cumulative
Inverter
run
time)
Fault
trace
and
fault
history
initialization
o2-12 Cannot
clear
0:
Disabled
(U2,
U3
are
held.)
1:
Initialize
Enabled
(U2,
U3
are
cleared
and
o2-12
returns
to
0.)
Fault
history U3-01
to
U3-20
Four
fault
history
records
are
stored.
U3-01
to
U3-08
are
enabled.
Serial
communications
addresses
90H
to
97H
are
enabled.
(800H
to
813H
are
disabled)
Ten
fault
history
records
are
stored.
U3-01
to
U3-20
are
enabled.
Serial
communications
addresses
800H
to
813H
and
90H
to
97H
are
both
enabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals