EasyManuals Logo

Omron SYSDRIVE 3G3RV Series User Manual

Omron SYSDRIVE 3G3RV Series
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #203 background imageLoading...
Page #203 background image
P
arameter Tables
5
-
7
7
U1-14
Software
No.
(flash
memory)
(Manufacturer’s
ID
number) (Cannot
be
output.) - A A A 4DH
FLASH
ID
U1-15
Terminal
A1
input
voltage
Monitors
the
input
voltage
of
the
voltage
frequency
refer-
ence.
An
input
of
10
V
cor-
responds
to
100%.
10
V:
100%
(10
V)
(0
to
±
10
V
possible)
0.1% A A A 4EH
Term
A1
Level
U1-16
Terminal
A2
input
voltage
Monitors
the
input
voltage
of
the
multi-function
analog
input.
An
input
of
10
V
corre-
sponds
to
100%.
10
V:
100%
(10
V)
(0
to
±10
V
possible)
0.1% A A A 4FH
Term
A2
Level
U1-18
Motor
sec-
ondary
cur-
rent
(Iq)
Monitors
the
calculated
value
of
the
motor
secondary
current.
The
motor
rated
secondary
current
corresponds
to
100%.
10
V:Motor
rated
secondary
current)
(0
to
±10
V
output)
0.1% A A A 51H
Mot
SEC
Current
U1-19
Motor
excit-
ing
current
(Id)
Monitors
the
calculated
value
of
the
motor
excitation
current.
The
motor
rated
secondary
current
corresponds
to
100%.
10
V:Motor
rated
secondary
current)
(0
to
±10
V
output)
0.1% No No A 52H
Mot
EXC
Current
U1-20
Output
fre-
quency
after
soft-start
Monitors
the
output
fre-
quency
after
a
soft
start.
The
frequency
given
does
not
include
compensations,
such
as
slip
compensation.
The
unit
is
set
in
o1-03.
10
V:
Max.
frequency
(0
to
±
10
V
possible)
0.01
Hz
AAA 53H
SFS
Output
U1-21
ASR
input Monitors
the
input
to
the
speed
control
loop.
The
maximum
frequency
corresponds
to
100%.
10
V:
Max.
frequency
(0
to
±
10
V
possible)
0.01
%
No A No 54H
ASR
Input
U1-22
ASR
output Monitors
the
output
from
the
speed
control
loop.
The
motor
rated
secondary
current
corresponds
to
100%.
10
V:Motor
rated
secondary
current)
(0
to
±
10
V
possible)
0.01
%
No A No 55H
ASR
Output
U1-24
PID
feed-
back
value
Monitors
the
feedback
value
when
PID
control
is
used.
The
input
for
the
max.
fre-
quency
corresponds
to
100%.
10
V:
Max.
frequency
(0
to
±
10
V
possible)
0.01
%
AAA 57H
PID
Feed-
back
U1-26
Output
volt-
age
refer-
ence
(Vq)
Monitors
the
Inverter
inter-
nal
voltage
reference
for
motor
secondary
current
control.
10
V:
200
VA C
(400 VAC)
(0
to
±
10
V
possible)
0.1
V
No No A 59H
Voltage
Ref
(Vq)
Param-
eter
Number
Name
Description
Output Signal Level Dur-
ing Multi-Function Analog
Output
Min.
Unit
Control Methods
Register
LCD
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals