Table 10.1 Parameters
No. Name
Fac-
tory
Setting
Set-
ting
No. Name
Fac-
tory
Setting
Set-
ting
A1-00
Language
selection
for
digital
operator
display
1
*1
b5-14
PID
feedback
command
loss
detec-
tion
time
1.0
A1-01 Parameter
access
level 2 b5-15 PID
sleep
function
operation
level 0.0
A1-02 Control
method
selection
0
*1
b5-16 PID
sleep
operation
delay
time 0.0
A1-03 Initialize 0 b5-17
Acceleration/deceleration
time
for
PID
reference
0.0
A1-04 Password 0 b5-18 PID
set
point
selection 0
A1-05 Password
setting 0 b5-19 PID
set
point 0.0
A2-01
to
A2-32
User
setting
parameters - b6-01 Dwell
frequency
at
start 0.0
b1-01 Reference
selection 1 b6-02 Dwell
time
at
start 0.0
b1-02 Operation
method
selection 1 b6-03 Dwell
frequency
at
stop 0.0
b1-03 Stopping
method
selection 0 b6-04 Dwell
time
at
stop 0.0
b1-04 Prohibition
of
reverse
operation 0 b8-01 Energy-saving
mode
selection 0
b1-06 Read
sequence
input
twice 1 b8-02 Energy-saving
gain
0.7
*4
b1-07
Operation
selection
after
switching
to
remote
mode
0 b8-03 Energy-saving
filter
time
constant
0.50
*5
b1-08
Run
command
selection
in
pro-
gramming
modes
0 b8-04 Energy-saving
coefficient
*6
b2-01
Zero
speed
level
(DC
injection
braking
starting
frequency)
0.5 b8-05
Power
detection
filter
time
con-
stant
20
b2-02 DC
injection
braking
current 50 b8-06 Search
operation
voltage
limiter 0
b2-03 DC
injection
braking
time
at
start 0.00 C1-01 Acceleration
time
110.0
b2-04 DC
injection
braking
time
at
stop 0.50 C1-02 Deceleration
time
110.0
b3-01 Speed
search
selection
2
*2
*3
C1-03 Acceleration
time
210.0
b3-02 Speed
search
operating
current
120
*2
C1-04 Deceleration
time
210.0
b3-03 Speed
search
deceleration
time 2.0 C1-05 Acceleration
time
310.0
b3-05 Speed
search
wait
time 0.2 C1-06 Deceleration
time
310.0
b4-01 Timer
function
ON-delay
time 0.0 C1-07 Acceleration
time
410.0
b4-02 Timer
function
OFF-delay
time 0.0 C1-08 Deceleration
time
410.0
b5-01 PID
control
mode
selection 0 C1-09 Deceleration
stop
time 10.0
b5-02 Proportional
gain
(P) 1.00 C1-10 Accel/decel
time
setting
unit 1
b5-03 Integral
(I)
time 1.0 C1-11
Accel/decel
time
switching
fre-
quency
0.0
b5-04 Integral
(I)
limit 100.0 C2-01
S-curve
characteristic
time
at
acceleration
start
0.20
b5-05 Derivative
(D)
time 0.00 C2-02
S-curve
characteristic
time
at
acceleration
end
0.20
b5-06 PID
limit 100.0 C2-03
S-curve
characteristic
time
at
deceleration
start
0.20
b5-07 PID
offset
adjustment 0.0 C2-04
S-curve
characteristic
time
at
deceleration
end
0.00
b5-08 PID
primary
delay
time
constant 0.00 C3-01 Slip
compensation
gain
0.0
*3
b5-09
PID
output
characteristics
selec-
tion
0 C3-02
Slip
compensation
primary
delay
time
2000
*2
b5-10 PID
output
gain 1.0 C3-03 Slip
compensation
limit 200
b5-11 PID
reverse
output
selection 0 C3-04
Slip
compensation
selection
during
regeneration
0
b5-12
Selection
of
PID
feedback
com-
mand
loss
detection
0 C3-05
Output
voltage
limit
operation
selection
0
b5-13
PID
feedback
command
loss
detec-
tion
level
0 C4-01 Torque
compensation
gain 1.00