EasyManua.ls Logo

Omron SYSDRIVE 3G3RV Series

Omron SYSDRIVE 3G3RV Series
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
0
-
14
Parameters
Factory
settings
are
given
in
the
following
table.
These
settings
are
for
a
200-V
class
Inverter
of
0.4
kW
set
to
factory
set
control
method
(open
loop
vector
control).
Table 10.1 Parameters
No. Name
Fac-
tory
Setting
Set-
ting
No. Name
Fac-
tory
Setting
Set-
ting
A1-00
Language
selection
for
digital
operator
display
1
*1
b5-14
PID
feedback
command
loss
detec-
tion
time
1.0
A1-01 Parameter
access
level 2 b5-15 PID
sleep
function
operation
level 0.0
A1-02 Control
method
selection
0
*1
b5-16 PID
sleep
operation
delay
time 0.0
A1-03 Initialize 0 b5-17
Acceleration/deceleration
time
for
PID
reference
0.0
A1-04 Password 0 b5-18 PID
set
point
selection 0
A1-05 Password
setting 0 b5-19 PID
set
point 0.0
A2-01
to
A2-32
User
setting
parameters - b6-01 Dwell
frequency
at
start 0.0
b1-01 Reference
selection 1 b6-02 Dwell
time
at
start 0.0
b1-02 Operation
method
selection 1 b6-03 Dwell
frequency
at
stop 0.0
b1-03 Stopping
method
selection 0 b6-04 Dwell
time
at
stop 0.0
b1-04 Prohibition
of
reverse
operation 0 b8-01 Energy-saving
mode
selection 0
b1-06 Read
sequence
input
twice 1 b8-02 Energy-saving
gain
0.7
*4
b1-07
Operation
selection
after
switching
to
remote
mode
0 b8-03 Energy-saving
filter
time
constant
0.50
*5
b1-08
Run
command
selection
in
pro-
gramming
modes
0 b8-04 Energy-saving
coefficient
*6
b2-01
Zero
speed
level
(DC
injection
braking
starting
frequency)
0.5 b8-05
Power
detection
filter
time
con-
stant
20
b2-02 DC
injection
braking
current 50 b8-06 Search
operation
voltage
limiter 0
b2-03 DC
injection
braking
time
at
start 0.00 C1-01 Acceleration
time
110.0
b2-04 DC
injection
braking
time
at
stop 0.50 C1-02 Deceleration
time
110.0
b3-01 Speed
search
selection
2
*2
*3
C1-03 Acceleration
time
210.0
b3-02 Speed
search
operating
current
120
*2
C1-04 Deceleration
time
210.0
b3-03 Speed
search
deceleration
time 2.0 C1-05 Acceleration
time
310.0
b3-05 Speed
search
wait
time 0.2 C1-06 Deceleration
time
310.0
b4-01 Timer
function
ON-delay
time 0.0 C1-07 Acceleration
time
410.0
b4-02 Timer
function
OFF-delay
time 0.0 C1-08 Deceleration
time
410.0
b5-01 PID
control
mode
selection 0 C1-09 Deceleration
stop
time 10.0
b5-02 Proportional
gain
(P) 1.00 C1-10 Accel/decel
time
setting
unit 1
b5-03 Integral
(I)
time 1.0 C1-11
Accel/decel
time
switching
fre-
quency
0.0
b5-04 Integral
(I)
limit 100.0 C2-01
S-curve
characteristic
time
at
acceleration
start
0.20
b5-05 Derivative
(D)
time 0.00 C2-02
S-curve
characteristic
time
at
acceleration
end
0.20
b5-06 PID
limit 100.0 C2-03
S-curve
characteristic
time
at
deceleration
start
0.20
b5-07 PID
offset
adjustment 0.0 C2-04
S-curve
characteristic
time
at
deceleration
end
0.00
b5-08 PID
primary
delay
time
constant 0.00 C3-01 Slip
compensation
gain
0.0
*3
b5-09
PID
output
characteristics
selec-
tion
0 C3-02
Slip
compensation
primary
delay
time
2000
*2
b5-10 PID
output
gain 1.0 C3-03 Slip
compensation
limit 200
b5-11 PID
reverse
output
selection 0 C3-04
Slip
compensation
selection
during
regeneration
0
b5-12
Selection
of
PID
feedback
com-
mand
loss
detection
0 C3-05
Output
voltage
limit
operation
selection
0
b5-13
PID
feedback
command
loss
detec-
tion
level
0 C4-01 Torque
compensation
gain 1.00

Table of Contents