I
nstalling and Wiring Option Cards
2
-
5
1
Shielded twisted-pair wires must be used for signal lines.
Do not use the pulse generator's power supply for anything other than the pulse generator (encoder).
Using it for another purpose can cause malfunctions due to noise.
The length of the pulse generator's wiring must not be more than 30 meters.
Fig 2.36 Wiring an Open-collector Input
Fig 2.37 I/O Circuit Configuration of the 3G3FV-PPGA2
Three-phase,
200 VAC (400 VAC) Inverter
+12 V power supply
0 V power supply
Open collector output (A/B phase)
Pulse 0 V
Pulse monitor output
R/L1
V/T2
W/T3
U/T1
V/T2
W/T3
4CN
4CN
E
E
1
2
3
4
5
6
7
8
TA1
TA2 (E)
3G3FV-PPGA2
E6B2-CWZ6C
PG power
supply
+12 V
Short for
open-col-
lector
input
Pulse
input
Pulse input
Pulse
monitor
output