FP2/FP2SHSpecifications
10 − 6
10.1 Specifications
Item
FP2 CPU
FP2−C1 (AFP2211), FP2−C1D (AFP2212), FP2−C1SL (AFP2214)
Differential points Unlimited number of points
Auxiliary timer Unlimited number of points, down type timer (0.01 to 327.67s)
Shift register Max. 253 points
Master control relay points (MCR) 256 points
Number of labels (JP and LOOP) 256 points
Number of step ladder 1,000 steps (* Note 3)
Number of subroutine 100 subroutines
Number of interrupt program 1 program (periodical interrupt: allows setting of the time interval within the
range from 0.5ms to 1.5s)
Comment input function Available (* Note 6)
Sampling trace function Max. 1,000 samples (4,000 words) for 16 contacts and 3 words
(* Note 2)
Clock/calendar function
Available (year, month, day, hour, minute, second and day of week)
(* Notes 6 and 7)
Link functions Inter−PLC link, computer link, remote programming, modem and data
transfer
Self-diagnostic functions W atchdog timer , memory malfunction detection, I/O malfunction detection,
backup battery malfunction detection, program syntax check, etc.
Other functions ROM operation function (* Note 8), program block edition during RUN
mode, forced input/output, interrupt processing, test run, constant scan
and machine language program
Memory backup time (lithium battery
storage time)
CPU only Min. 10,000 hours
(typical: approx. 13,000 hours)
FP2−EM2,
FP2−EM3
Min. 8,000 hours
(typical: approx. 12,000 hours)
FP2−EM6 Min. 8,500 hours
(typical: approx. 12,500 hours)
FP2−EM7 Min. 10,000 hours
(typical: approx. 13,000 hours)