Chapter 1 Specifications
HF Series X-ray Generators - Service Manual Revision W
Quantum Medical Imaging 1-13
Table 1-3. HF Series Generators - Electrical Wiring Requirements
(380-480 VAC Three-Phase Input Units)
QG-32-3,
QG-40-3
QG-50
QG-65
QG-80
32
(QG-32
-3)
40
(QG-40-3)
50
65
80
G
E
N
E
R
A
T
O
R
M
O
D
E
L
N
O
.
MAX. POWER
O
UTPUT (kW)
N
O
M
I
N
A
L
L
I
N
E
V
O
L
T
A
G
E
(
V
A
C
)
DISCONNECT
TO GENERATOR
15 FT. (5 M) MAX.
*
S
E
R
V
I
C
E
R
A
T
I
N
G
*
R
E
C
O
M
M
E
N
D
E
D
D
I
S
T
R
I
B
U
T
I
O
N
T
R
A
N
S
F
O
R
M
E
R
C
A
P
A
C
I
T
Y
MAX. INPUT LINE
RESISTANCE
(AT FULL-LOAD RMS)
3
0
#
6
A
W
G
6
0
A
M
P
S
5
0
K
V
A
0
.
2
3
O
H
M
S
3
8
0
#
4
A
W
G
8
0
A
M
P
S
6
5
K
V
A
0
.
1
7
O
H
M
S
3
8
0
#
4
A
W
G
9
0
A
M
P
S
8
0
K
V
A
0
.
1
2
O
H
M
S
3
8
0
#
4
A
W
G
1
0
0
A
M
P
S
1
0
0
K
V
A
0
.
1
0
O
H
M
S
4
4
0
#
6
A
W
G
6
0
A
M
P
S
5
0
K
V
A
0
.
3
3
O
H
M
S
4
4
0
#
6
A
W
G
8
0
A
M
P
S
6
5
K
V
A
0
.
2
0
O
H
M
S
4
4
0
#
4
A
W
G
9
0
A
M
P
S
8
0
K
V
A
0
.
1
7
O
H
M
S
4
4
0
#
4
A
W
G
1
0
0
A
M
P
S
1
0
0
K
V
A
0
.
1
4
O
H
M
S
4
8
0
#
6
A
W
G
5
0
A
M
P
S
5
0
K
V
A
0
.
4
O
H
M
S
4
8
0
#
6
A
W
G
7
5
A
M
P
S
6
5
K
V
A
0
.
2
4
O
H
M
S
4
8
0
#
4
A
W
G
9
0
A
M
P
S
8
0
K
V
A
0
.
1
9
O
H
M
S
4
8
0
#
4
A
W
G
1
0
0
A
M
P
S
1
0
0
K
V
A
0
.
1
6
O
H
M
S
QG-320,
QG-3200,
QGV
-32-3,
QG-400,
QG-4000,
QG
V-40-3
QG-500,
Q
G-5000,
Q
GV-50
QG-6500,
QGV-65
QG-8000,
QGV-80
G
E
N
E
R
A
T
O
R
C
A
T
A
L
O
G
N
O
.
*NOTE: All installations must meet the requirements of local electrical codes.
The above values are recommended as typical (unless otherwise specified).
*
1.
Input Voltage: 380-480 (±10%) VAC 50/60 Hz (configured at time of installation)
. Voltage is three-phase Y-configuration, measured line-to-line, balanced to earth
ground. (Note: Additional Neutral wire may be used if required by local electrical code.)
7. Ground wire size is 4 AWG.
8. Specifications are subject to change.
All wire must be copper.
2. Actual wire size depends on power quality and distance between mains power
and the generator.
3. All wiring and grounding must be in accordance with National
Electric Code (NFPA #70) or local electrical codes.
4. The disconnect switch must be located within reach of the operator.
5. .
6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum ODYSSEY HF Series and is the answer not in the manual?

Quantum ODYSSEY HF Series Specifications

General IconGeneral
BrandQuantum
ModelODYSSEY HF Series
CategoryMedical Equipment
LanguageEnglish

Related product manuals