Remote Control
R&S
®
FSPN
376User Manual 1179.4363.02 ─ 01
[SENSe:]SPURs:FILTer:SAVE......................................................................................... 378
[SENSe:]SPURs:FILTer:LOAD.........................................................................................379
[SENSe:]SPURs:COLor..................................................................................................379
DISPlay[:WINDow<n>]:TRACe<t>:SPURs:SUPPress <State>
This command turns spur removal for a specific trace on and off.
Suffix:
<n>
.
1..n
Window
<t> 1..n
Trace
Parameters:
<State> ON | OFF | 1 | 0
*RST: OFF
Manual operation: See "Hiding spurs" on page 120
DISPlay[:WINDow<n>]:TRACe<t>:SPURs:THReshold <Threshold>
This command defines a level threshold for spur removal.
Prerequisites for this command
Turn on spur removal (DISPlay[:WINDow<n>]:TRACe<t>:SPURs:THReshold
).
Suffix:
<n>
.
1..n
Window
<t> 1..n
Trace
Parameters:
<Threshold> <numeric value>
*RST: 0
Default unit: dB
Example: See DISPlay[:WINDow<n>]:TRACe<t>:SMOothing[:
STATe].
Manual operation: See "Hiding spurs" on page 120
[SENSe:]SPURs:SORT <Order>
This command selects the sort order of the spurs in the spur list.
Parameters:
<Order> POWer
Sorts spurs according to their power.