1.SC Codes
182
Error Name/Error Condition/Major Cause/Solution
Stacker 2 (Downstream): Proof Tray JG Motor Error
When moving to the home position, home position was not detected within
specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
Connecter disconnected
Overload
Home position sensor defective
Motor driver overcurrent
Motor driver overheat detected
Check the Proof Tray JG Motor/Proof Tray JG HP Sensor connection.
Replace the Proof Tray JG Motor/Proof Tray JG HP Sensor.
Error Name/Error Condition/Major Cause/Solution
Stacker 1 (Upstream): Shift Tray JG Motor Error
Stacker 2 (Downstream): Shift Tray JG Motor Error
When moving to the home position, home position was not detected within
specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
Motor defective
Connecter disconnected
Overload
Home position sensor defective
Motor driver overcurrent
Motor driver overheat detected
Check the Shift Tray JG Motor/Shift Tray JG HP Sensor connection.
Replace the Shift Tray JG Motor/Shift Tray JG HP Sensor.
Error Name/Error Condition/Major Cause/Solution
Stacker 1 (Upstream): Shift Motor Error