1.SC Codes
380
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
Error generated when an invalid function is detected
1. Reboot the DFE.
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC911-
44
B
Recommended amount of memory not found
-
Error generated when the amount of memory is less than the recommended
value
The memory or board may be defective.
1. Reboot the DFE.
2. Replace the DIMM of the DFE.
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC911-
45
B
Recommended number of processors not found
-
Error generated when the number of processors is less than the recommended
value
The CPU or board may be defective.
1. Reboot the DFE.
2. Replace the CPU of the DFE.
3. Replace CPU fan of the DFE
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC911-46
B
File read error, hard disk
-
HDD file read error
1. Reboot the DFE.
2. Reinstall the DFE System.
3. Replace the HDD of the DFE.
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC911-47
B
File write error, hard disk
-
HDD file write error
1. Reboot the DFE.
2. Reinstall the DFE System.
3. Replace the HDD of the DFE.