7.4.2 Ethernet.................................................................................... 93
7.5 Time synchronization................................................................................ 94
7.6 Reading configuration.............................................................................. 94
7.7 Identification............................................................................................. 95
7.8 Protocol settings....................................................................................... 96
7.8.1 EtherCAT FSoE configuration.................................................. 96
7.9 Application................................................................................................ 97
7.10 Monitoring plane....................................................................................... 98
7.10.1 Parameters for the monitoring plane..................................... 98
7.10.2 Parameters for the safety laser scanner................................ 101
7.11 Reference contour field............................................................................ 103
7.12 Fields......................................................................................................... 104
7.12.1 Using the field editor............................................................... 105
7.12.2 Creating field set templates.................................................... 108
7.12.3 Importing and exporting field sets and fields........................ 109
7.12.4 Background image................................................................... 109
7.12.5 Settings for the field editor..................................................... 110
7.12.6 Editing fields using coordinates.............................................. 111
7.12.7 Drawing in points that cannot be monitored......................... 113
7.12.8 Defining global geometry........................................................ 114
7.12.9 Enable propose field................................................................ 114
7.13 Inputs and outputs................................................................................... 116
7.14 Monitoring cases...................................................................................... 118
7.14.1 Settings for monitoring case tables........................................ 118
7.14.2 Settings for monitoring cases................................................. 119
7.14.3 Input condition......................................................................... 119
7.14.4 Cut-off paths............................................................................ 119
7.14.5 Assigning field sets.................................................................. 120
7.14.6 Assigning a defined cut-off behavior...................................... 120
7.14.7 Importing and exporting monitoring case tables................... 121
7.15 Simulation................................................................................................. 122
7.16 Data output............................................................................................... 123
7.17 Transfer..................................................................................................... 124
7.18 Starting and stopping safety function..................................................... 125
7.19 EtherCAT overview.................................................................................... 126
7.20 Reports...................................................................................................... 127
7.21 Service....................................................................................................... 128
7.21.1 Device restart........................................................................... 128
7.21.2 Factory settings........................................................................ 128
7.21.3 Managing passwords............................................................... 128
7.21.4 Access management............................................................... 129
7.21.5 Optics cover calibration........................................................... 130
7.21.6 Compare configuration............................................................ 131
8 Commissioning.................................................................................. 132
8.1 Safety......................................................................................................... 132
CONTENTS
8025220/1L9Q/2023-08-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherCA
5
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK EtherCAT microScan3 and is the answer not in the manual?

SICK EtherCAT microScan3 Specifications

General IconGeneral
Scanning angle275°
InterfacesEtherCAT
Protection classIP65
Supply voltage24 V DC
Resolution for protective field30 mm
Operating voltage24 V DC
Scanning range5.5 m
Number of fields128
Number of monitoring cases128
Response time30 ms
Operating temperature0 °C to 50 °C
Field of applicationIndustrial safety
Light sourceInfrared laser, 905 nm
Connection typeM12
Weight1.2 kg

Related product manuals