EasyManuals Logo

Siemens optiPoint 410 entry User Manual

Siemens optiPoint 410 entry
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
Extended Administration
100
Behaviour regarding the Survivability settings
Please make sure all parameters are set completely and accurately.
Backup Server not entered and activated
• Backup IP address or DNS name:
– No IP address was entered (! page 219
, ! page 147)
• Backup registration:
– The Checkbox for the "Backup registration" feature is not marked
(! page 147) and/or the feature was not activated in the telephone
menu (! page 220)
The telephone only registers at the server (Hipath8000). In case the server
fails or is not available, the message "Server not found" is displayed. No
calls can be made.
Backup Server is entered, but not activated
• Backup IP address or DNS name:
– IP address is entered (e.g. 192.168.1.1 ! page 219, ! page 147)
• Backup registration:
– The Checkbox for the "Backup registration" feature is not marked
(! page 147) and/or the feature was not activated in the telephone
menu (! page 220).
The telephone only registers at the server (Hipath8000). In case the server
fails or is not available, no message is displayed. Even after restarting the
telephone no message is displayed, and the display looks as if the tele-
phone had registered at the HiPath8000. However, outbound calls are pos-
sible via the backup server, while inbound calls to this telephone are not
possible as it is not registered at the backup server.
Backup Server is entered and activated
• Backup IP address or DNS name:
– IP address is entered (e.g. 192.168.1. ! page 219, ! page 147)
• Backup registration:
– The Checkbox for the "Backup registration" feature is marked
(! page 147) and the feature is activated in the telephone menu
(! page 220).
The telephone registers both at the server (Hipath8000) and the backup
server. In case the Hipath8000 fails or is not available, the message "Tem-
porary limited mode" is displayed. Both outbound and inbound calls are
possible via the backup server..

Table of Contents