SINUMERIK operating mode
6.2 Networking
ITC V3, ITC V3 PRO
146 Operating Instructions, 03/2024, A5E42761061-AF
Example:
[Station]
maxhostindex=2
/* Number of nodes that are defined under
[host 1] and [host 2].
mcpIndex=192
tcuIndex=1
eksIndex=0
[host_1]
Address=192.168.214.1
/* Address of the NCU to which the
connection is established during booting.
[host_2]
Address=157.163.230.202
/* Address of the PC
password=123456
/* Password of the VNC server on the PC
Switching over between the nodes
With the menu back key + MENU SELECT, the following actions are triggered:
The ITC name is displayed in the header of the displayed window, e.g. ITC1.
A selection list for connecting to the other nodes is displayed on the ITC.
6.2.4 Service and diagnostics
6.2.4.1 Operation of the ITC main menu
Displaying the ITC menu
With touch screens: Simultaneously touch the left-hand and right-hand lower corner of
the active display area with one finger at a time.
With connected keyboard: Press the menu back key and the <MENU SELECT> key