SINUMERIK operating mode
6.2 Networking
ITC V3, ITC V3 PRO
Operating Instructions, 03/2024, A5E42761061-AF
155
• "Virtual Keyboard" (Auto/On/Off)
Specifies whether a virtual keyboard is shown on the screen for touch screens.
Depending on the panel features (Auto), the HMI decides whether a touch screen or
keyboard is available.
This parameter can also be set manually (On/Off).
• "Software Caps-Lock" (Auto/On/Off)
The HMI can manage the Caps-Lock status of a keyboard in the software itself, when, for
example, the key is not available. This is normally (Auto) switched on via a display
machine data item. This machine data item can be overwritten individually for the ITC
with the setting (On/Off).
• "Screen Rotation" (0°/90°/180°/-90°/Auto)
Specifies in which angle the screen is to be rotated in the software. This is useful when the
Panel is to be rotated during installation.
For the "Auto" setting, the rotation of the display is taken from the Panel.
• "Old VNC Password"
If a password has already been set, it must be entered here so that it can be changed. If no
password has been set, this field is grayed-out. The existing password can also be deleted
if, after entering the old password, no new password is to be entered at "Set VNC
Password" and "Repeat Password".
• "Set VNC Password"
Assign a password, which is stored in the ITC and, if required, sent to the server when the
VNC connection is established.
• "Repeat Password"
Repeat the password entered at "Set VNC Password".
• "Enable touch capability" (yes/no)
Specifies whether the screen can be operated by touch. If you deactivate this option, you
will need a keyboard to reactivate it.
The values are applied and stored with "OK". You can also make any subsequent adaptations
or changes via the user interface in the "Setup" operating area > menu forward key > "OPs"
softkey.
6.2.4.5 Operation of the menu for a new ITC or replacement ITC
Registering a new ITC
When an unknown ITC not yet registered with the boot server is started, a selection menu
containing the "New" and "Replacement for existing panel" items is displayed. The
accessibility of all the registered ITCs is tested in the background.