ITC Operating mode
5.5 Assigning device parameters
ITC V3, ITC V3 PRO
Operating Instructions, 03/2024, A5E42761061-AF
91
Restore to factory settings
Restoring factory settings has the following effects:
The default configuration file overwrites the configuration file. All connection data for the
network, remote access and web browser is reset. The language and screen brightness,
the settings and position of the taskbar and on-screen keyboard, and the background
image are reset.
NOTICE
Data loss restoring the factory settings
Back up the configuration file and then reload it (see above).
The administrator password is deleted and must be reassigned at next restart.
Procedure
Touch the "Restore to factory settings" button. The "Resetting to factory defaults" message
is shown on the touch screen. The device reboots automatically if you confirm this
message.
Alternative procedure
1. Switch off power to the device.
2. Press and hold the "Factory settings" button on the device and switch on the power supply
of the device again. The device restarts.
Use a sturdy blunt tool made of non-conductive material with a diameter of approximately
5 mm. The "Factory settings" button is next to the interface X1 P1 PROFINET (LAN).
3. Press and hold the "Factory settings" button until the boot procedure has finished and the
first commissioning dialog is displayed.
Service device remotely via VNC
Allows remote access to the device. The device has a VNC server for this purpose. With VNC
remote access, you can "Permit access to Desktop" or "Permit operation", in other works,
enable operation of the plant or machine from the device. You also set the "port" and the
"password" for remote access. Remote access must always be protected by a password, i.e. an
entry in the "Password" field is required.
Activating remote configuration
You can use the "Remote configuration" option, "Activate (Web)" to specify whether or not it
is allowed to configure the Industrial Thin Client via the Web browser of another device. The
configuration settings of the Industrial Thin Client are accessed via an encrypted connection
in HTML5 format, which means access must be made with a Web browser that supports
HTML5 and encrypted connections (https).