Technical specifications
8.3 Mechanical environmental conditions
ITC V3, ITC V3 PRO
Operating Instructions, 03/2024, A5E42761061-AF
175
8.3 Mechanical environmental conditions
8.3.1 Storage conditions
The following information is for a device that is transported and stored in its original
packaging.
Vibration according to IEC 60068-2-6 5 .. 8.4 Hz, deflection 3.5 mm
8.4 ... 500 Hz, acceleration 1 g
Shock according to IEC 60068-2-27
2
8.3.2 Operating conditions
The following information applies to a device installed according to the specifications in these
operating instructions.
Built-in units
Vibration according to IEC 60068-2-6
5 ... 8.4 Hz, deflection 3.5 mm
8.4 ... 200 Hz, acceleration 1 g
Shock according to IEC 60068-2-27
2
Shock pulses within the specified range can be transferred to the display but do not impact
the functionality of the device.
PRO devices
Vibration according to IEC 60068-2-6 10 ... 58 Hz, deflection 0.0375 mm
58 ... 200 Hz, acceleration 0.5 g
Shock according to IEC 60068-2-27
2
Shock pulses within the specified range can be transferred to the display but do not impact
the functionality of the device.