Technical specifications
8.2 Electromagnetic compatibility
ITC V3, ITC V3 PRO
174 Operating Instructions, 03/2024, A5E42761061-AF
Sinusoidal interference
The following table shows the EMC behavior of the modules with respect to sinusoidal
interference. This requires the HMI device to meet the specifications and directives for
electrical installation.
HF radiation (electromagnetic fields)
according to IEC 61000-4-3
80% amplitude modulation at 1 kHz
• on 10 V/m in the range of 80 MHz to 1 GHz
• on 3 V/m in the range of 1.4 to 6 GHz
HF current feed on cables and cable
shields according to IEC 61000-4-6
Test voltage 10 V at 80% amplitude modulation of 1 kHz in
the range from 150 kHz to 80 MHz
Magnetic field strength according to
IEC 61000-4-8
Emission of radio interference
The following table shows the interference emissions from electromagnetic fields in
accordance with EN/IEC 61000-6-4, measured at the following distance.
Radiated emission (interference emission)
< 40 dB (μV/m) quasi-peak
< 47 dB (μV/m) quasi-peak
< 76 dB peak and < 56 dB average
< 80 dB peak and < 60 dB average
Emission of radio interference voltages
< 89 dB quasi peak and < 76 dB average
< 83 dB quasi peak and < 70 dB average
See also
EMC information in section "Notes about usage (Page 38)".