EasyManua.ls Logo

Siemens Simodrive 611 - Page 142

Siemens Simodrive 611
380 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
05.01
5.8 Control module SIMODRIVE 611 universal E
5-142
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) 05.01 Edition
Table 5-21 Encoder interface for TTL encoders (X472)
Pin Function Type Technical data
No. Desig.
1)
X472 Connector type: DSub socket, 15pin
1 P_Encoder V S Recommendation for TTL encoders:
2 M_Encoder V
Order No. (MLFB): 6FX20012VB02
3 A I
Encoder pulse number = 1024
V = Spare retainer for connection types A, C, E or G
S
4 *A I
S Cabling
5 Reserved
Possibility of
Max. cable length: 15 m
6 B
connecting to a
power supply for an
I
Recommendation for encoder cables:
Order No. (MLFB): 6FX20022CA111
VV
0
7 *B
additional measuring
system (TTL encoder,
I
Order No. (MLFB): 6FX20022CA111
VV
0
V = Space retainer for cable type (length, ...)
8 Reserved
system (TTL encoder,
encoder 3).
Reference:
9 P_Encoder
The data is
V
/NCZ/ Catalog, Accessories and Equipment
S
10 R
transferred to a
higherlevel control
I
S
Encoder power supply
Voltage: 5.1 V $2 %
11 M_Encoder
system via
PROFIBUS.
V
Voltage: 5.1 V
$
2 %
Shortcircuit proof
12 *R I
Shortcircuit proof
Max. current: 300 mA
13
Max. shortcircuit current: A3.5
14
Reserved
S Encoder limiting frequency
15
TTL encoder: 1 MHz
1) I: Input; V: supply
Encoder interface
for TTL encoders
(X472)
5 Control Modules

Table of Contents

Other manuals for Siemens Simodrive 611