6.4 Interface overview
6-178
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Table 6-6 Interface description for NE modules
Term.
No.
Terminals
available in
3)
Max. cross–
section
10)
Typ. voltage/ limit values
Type
1)
FunctionDesig.
X151 Equipment bus I/O Various Ribbon cable I/R, UI, monito-
ring module,
pulsed resistor
M500
P500
1U1
2U1
1V1
2V1
1W1
2W1
X181
X181
X181
X181
X181
X181
X181
X181
DC link power supply
DC link power supply
Output L1
Input L1
Output L2
Input L2
Output L3
Input L3
I
I
O
I
O
I
O
I
DC –300 V
DC +300 V
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
I/R, UI,
monitoring
module
7
45
44
10
15
2)
R
6)
X141
X141
X141
X141
X141
X141
P24
P15
N15
N24
M
RESET
O
O
O
O
O
I
+20.4...28.8 V/50 mA
+15 V/10 mA
–15 V/10 mA
–20.4...28.8 V/50 mA
0 V
Term.15/R
E
= 10 kΩ
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
I/R, UI,
monitoring
module
5.3
5.2
5.1
63
2)
9
2)8)
9
2)8)
64
2)
19
X121
X121
X121
X121
X121
X121
X121
Relay contact
Group signal
I
2
t/motor temp.
Pulse enable
Enable voltage
Enable voltage
Drive enable
Enable voltage,
reference potential
NC
NO
I
I
O
O
I
50 V DC/0.5 A/12 VA max
5 V DC/3 mA min
+13 V...30 V/R
E
= 1.5 kΩ
+24 V
+24 V
+13 V...30 V/R
E
= 1.5 kΩ
0 V
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
I/R, UI,
monitoring
module
74
nc
73.2
73.1
nc
72
X111
X111
X111
X111
X111
X111
Relay contact
Ready signal
NC
I
I
NO
1–ph. 250 V AC/50 V DC/2
Amax. 5 V DC/3 mA min
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
I/R, UI,
monitoring
module
9
2)8)
112
2)
X161
X161
Enable voltage
Setting–up mode/
Standard mode
O
I
+24 V
+21 V...30 V/R
E
= 1.5 kΩ
1.5 mm
2
1.5 mm
2
I/R, UI, monito-
ring module
1) I = input; O = output; NC = NC contact; NO = NO contact; (for signal, NO = high; NC = low)
2) Terminal 19 is the reference ground (connected in the module with 10 k to a general reference ground,
X131/terminal 15)
Terminal 15 may neither be connected to PE nor to terminal 19, furthermore, it is not permissible
that external voltage sources are connected to terminal 15. Terminal 19 may be connected to terminal X131.
The terminal may only be used to enable the associated drive group.
3) I/R = Infeed/regenerative feedback module; UI = Uncontrolled infeed; MM = Monitoring module;
PW = Pulse resistor module
4) The 1st number is valid for cable lugs. The 2nd number is valid for finely–stranded conductors without conn. sleeves.
5) The grounding bar is used to ground the DC link M rail through 100 kΩ (this should be preferably inserted;
if the system is subject to a high voltage test, the grounding bar should be opened).
6) RESET = reset the fault memory, edge–triggered for the complete drive group (terminal ”R” terminal 15 = RESET)
7) Terminal 111–213 positively–driven NC contact (for I/R 16 kW and UI 10 kW, only from Order No. [MLFB]:
6SN114V–1VV01–0VVV)
Terminals 111–113 NO contact, not positively driven
8) Maximum current load of terminal 9 with respect to 19: 0.5 A.
9) Only for UI 28 kW
10) For UL certification, only use copper cables designed for an operating temperature of w 60