4.1 Technical data
4-85
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Table 4-2 Technical data/power module, 1–axis version (additional power modules)
Internal cooling
External cooling
Hose cooling
Cooling type
6SN 1123–1AA0.–
6SN 1124–1AA0.–
6SN 1123–1AA0.–
0LA1
0LA1
–
Force
ventilated
0JA1
0JA1
0JA1
Force
ventilated
0KA1
0KA1
0KA1
Force
ventilated
To use 1FT6 motors/1FK6 motors/1FN motors
with control module 6SN11 18–0Bx11–xxxx
Rated current
Peak current
A
A
42
64
100
100
140
210
Power loss, total/
internal/external
3)
W 460 / 25 /
435
1300 / 170
/ 1130
1910 / 250
/ 1660
f
o
1)
X1
1)
kHz
%
3.3
55
3.3
55
3.3
55
To use 1FT6 motors/1FK6 motors/1FN motors
with control module 6SN11 18–0Dxxx–xxxx, 6SN11 18–xNxxx–xxxx
Rated current
Peak current
A
A
42
64
100
100
140
210
Power loss, total/
internal/external
3)
W 460 / 25 /
435
1300 / 170
/ 1130
1910 / 250
/ 1660
f
o
1)
X1
1)
kHz
%
4
55
4
55
4
55
General data for controlled infeed modules
Input voltage
Output voltage
Efficiency η
V
V
600/625/680 DC
3–ph. 0 to 430 V
0.98
Module width
Max. cross–section
2)4)
Weight, approx.:
Internal cooling
External cooling
mm
mm
2
kg
kg
150
50
13
13
300
95 or
2 x 35
26
26
300
150 or
2 x 50
28
28
fo = inverter clock frequency
1) X1 = reduction factor of the current, current de–rating from inverter clock frequency f
0
of the power transistors (Fig. 4-2)
2) The 1st number is valid for cable lugs, the 2nd number is valid for finely–stranded conductors without conn. sleeves.
3) If internal cooling or hose cooling is used, then only Pv
tot
should be considered.
4) For UL certification
:
only use copper cables designed for an operating temperature of w 60
4 Power Modules