5.2.5 Mounting position
Description
The 1FL2 mo
tor supports ange mounting only. It can be installed in three orientations as
shown in the following table.
Table 5-5 Type of construction according to IEC60034‑7
Designation Representation Description
IMB5
Standard
IMV1
The motor can be used in types of construction IM V1 and
IMV3 without res
triction.
IMV3
Note
IM V3 type of construction
When conguring
the IM V3 type of construction, pay attention to the permissible axial forces
and especially to the necessary degree of protection.
Mounting
5.2Motor
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
110 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB