EasyManua.ls Logo

Siemens SINAMICS SIMOTICS S200 PROFINET - User-Defined Parameter List; Backup and Restore; Overview

Siemens SINAMICS SIMOTICS S200 PROFINET
908 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.4.5.2 User-de󹪝ned parameter list
Overview
A user-de󹪝ned parameter list is a combination of speci󹪝c parameters from the standard
parameter list of the converter. These can be used to con󹪝gure frequently used user functions,
for example.
Description of function
To create a user-de󹪝ned parameter list, click in the function view "Parameter list".
With t
he user-de󹪝ned parameter lists, the web server provides the following functions:
Creating up to 20 user-de󹪝ned parameter lists
Con󹪝guring list properties
Name
Position or sequence of the tabs
Comment
Delete list
Exporting and importing user-de󹪝ned parameter lists
Export:
Export one or several user-de󹪝ned parameter lists.
The web server exports the lists exclusively as a json 󹪝le.
Export 󹪝les generated by the web server can be imported into a Startdrive project.
Import:
The list import function in the web server exclusively imports json 󹪝les.
User-de󹪝ned parameter lists exported via the web server or Startdrive as a json 󹪝le can be
imported into another drive of the same type via the web server.
Requirement: same drive type and same 󹪝rmware version
If values are changed, the data must be saved retentively.
7.4.6 Backup and restore
7.4.6.1 Overview
Overview
With "Backup and restore" you can back up parameters and other settings and restore the
settings again if necessary.
Commissioning (web server)
7.4Functions and menus
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 199

Table of Contents