The current device is replaced by the required replacement device.
If the two devices are not completely compatible with one another, then in the "Device view"
tab, the placeholder for the motor is displayed unspecied. You must reassign an appropriate
motor power.
8.5.1.3 Making detailed converter settings
Overview
You can congure the following details for the converter:
Table 8-1 Detailed converter settings in the inspector window
Group Settings
General
• Product information
Name data
•
Catalog information
Brief description, description of the components included, rmware version used
• Identication & Maintenance
Information and data to identify and localize a drive within a plant or system.
PROFINET interface [X150]
• General
• Etherne
t addresses
Subnet, IP address, subnet mask, PROFINET names
• Telegram conguration
– Telegrams of the closed-loop drive control: Send, receive
Details are contained in Chapter "Conguring telegrams (Page285)"
• Advanced options
– Interface options
– Media redundancy
– Clock cycle synchronization for local modules (isochronous mode)
– Real time settings
– Port [X150 P1] and port [X150 P2]
Module parameters
• Activation of channel diagnostics
Protection & Security
• Wizard for security settings
•
User Management & A
ccess Control (UMAC)
• Ports and protocols
• Encryption of drive data
Note: Information about these protection settings is provided in the Conguration Manual
SINAMICS Industrial Security or in the information system of the TIA Portal.
Ethernet commissioning in‐
terface [X127]
•
General
• Ethernet addresses:
– Subnet, IP address, subnet mask
Commissioning (Startdrive)
8.5Combining and conguring devices in the pr
oject
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
240 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB