7.3 Getting started
7.3.1 Calling the w
eb server
Overview
Converter commissioning takes place with the user interface of the web server.
Requirement
You have connected the converter and the operating unit via the service interface X127.
Procedure
To access the web server via the service interface X127, enter the IP address of the converter, e.g.
https://169.254.11.22, in the browser.
More information
Basic settings
When you call the web server for the 󹪝rst time, you are prompted to de󹪝ne the basic
settings.
If you have already made the basic settings, then the web server starts and opens the
home page. You can commission the converter, troubleshoot it, operate it, monitor it or
call up support through the support pages.
Alternative access via PROFINET interface X150
You can also access the web server via PROFINET interface X150.
To access the integrated web server, you must assign PROFINET interface X150 a valid IP
address (other than X127) using Startdrive.
Commissioning (web server)
7.3Getting started
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
172 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB