8.4 Procedures for device con󹪝guration and commissioning
8.4.1
Requirements
Description
Note
Onl
y in the o󹪠ine mode
The dr
ive components can only be combined and speci󹪝ed in the o󹪠ine mode. In the online
mode, all corresponding setting ranges are disabled in the device view and in the inspector
window.
Note
User manag
ement and secur
ity
SIN
AMICS converters of the latest generation generally have extended protection. This usually
has the e󹪜ect that, as a user, you have to log in to view or edit the converter data o󹪠ine as well
as online.
The most important protective measures in brief:
Project protection can be activated for Startdrive projects in the TIA Portal (o󹪠ine). If project
protection is activated, corresponding rights are required for access. Once project protection
has been activated, it cannot be deactivated.
A "Security Wizard" usually appears when creating new converters in the project. With the
help of this wizard, you can already make the most important security settings for this
converter within the project when creating the converter. After loading the project data into
the converter, the protection settings become e󹪜ective there.
To access a protected converter online, you ALWAYS need the corresponding access rights.
This also applies if no project protection is activated for the Startdrive project.
Detailed information on this topic is provided in the Con󹪝guration Manual SINAMICS Industrial
Security in Chapter "Security settings in Startdrive".
Note
Editing mode requir
ed for online commissioning
If you want to make important settings online, activation of the editing mode is mandatory.
Restore points that are required as a return point following a cancellation of the current online
parameterization are automatically created by the editing mode in the "guided quick startup"
(and in the "Parameterization" area) during con󹪝guration.
No separate editing mode is necessary in the "Rotate & optimize" area.
Note
Telegr
am con󹪝guration o󹪠ine
In the guided quick startup, telegram settings can in principle only be made o󹪠ine.
Commissioning (Startdrive)
8.4Procedures for device con󹪝guration and commissioning
SINAMICS S200 PR
OFINET servo drive system with SIMOTICS S-1FL2
230 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals