The converter backs up the following data and settings:
Communication interface settings
Parameters (including safety parameters)
Security settings
UMAC data
Web server settings:
Modi󹪝ed settings in window "Drive status" on the home page
User-de󹪝ned parameter lists
Support settings
Save changes manually/automatically
Displayed parameters (display standard parameters/all parameters):
Standard parameters
View all parameters
Display brightness
The converter 󹪝rmware 󹪝les are not backed up.
7.4.6.4 Restoring data from an unencrypted backup data
Requirement
You have an unencrypted backup 󹪝le of the converter on your operating unit.
Rights required for active user management (UMAC):
"Create backup or load drive data to Startdrive"
Procedure
1. Call the "Backup and restore" menu.
2. Navigate to the "Restore drive data from backup 󹪝le" area.
3. Use the "Click to select 󹪝le, or drag and drop 󹪝le here" button to select the backup 󹪝le.
4. To restore the drive data, proceed as described below depending on the speci󹪝c application.
This step is included in the following diagrams as step 3.
Commissioning (web server)
7.4Functions and menus
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
202 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB