8.4.3 Simple basic parameterization (online)
Overvie
w
The basic parameterization can be carried out in online mode as an alternative to oine mode.
Requirement
None
Procedure
Proceed as follows to perform basic parameterization in online mode:
1. Create or open a project with Startdrive.
2. Create device conguration in Startdrive oine.
– Insert the specify the SINAMICS drive in the project.
– Optional: Congure user management and make protection settings for the drive.
– Create and specify SINAMICS components.
– Make detailed settings for the drive and components.
3. Load project data to the target device.
4. Establish an online connection between Startdrive and the target device.
5. Make basic parameterization settings online via the guided quick startup in the editing mode.
– Make basic settings in the quick startup steps.
– Optimize commissioning.
Result
The motor rotates.
Commissioning (Startdrive)
8.4Procedures for device conguration and commissioning
SINAMICS S200 PR
OFINET servo drive system with SIMOTICS S-1FL2
232 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB