Corrective maintenance
13
13.1 Service and maintenance for the converter
13.1.1
Res
toring the converter to factory settings
13.1.1.1 Restoring factory settings via a commissioning tool
Description
The restoring to factory settings with a commissioning tool (web server, Startdrive) only deletes
the user-speci󹪝c parameterization of the converter, for example motor data.
The following settings are retained with the restoring:
Activation and settings of User Management & Access Control
The "IP con󹪝guration" and "Device name" communication settings of the service interface
(X127) and PROFINET interface (X150)
Installed 󹪝rmware on the converter
The restoring to factory settings with the commissioning tool is described in the following
sections:
Web server: Restore factory settings (Page207)
Startdrive: Restore factory settings (Page306)
13.1.1.2 Reset of all user-de󹪝ned settings to the factory setting via an SD card
Overview
The following user-de󹪝ned settings are stored in the converter:
Parameterization of the converter
Activation and settings of User Management & Access Control
"IP con󹪝guration" and "Device name" communication settings of the service interface (X127)
and PROFINET interface (X150)
Self-generated certi󹪝cates
User-de󹪝ned parameter lists in the web server
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2