10.4.2 Supported telegrams
Overvie
w
The converter supports standard telegrams and Siemens telegrams for speed control and
position control.
Description of function
From the perspective of the converter, the received process data represents the receive words
and the process data to be sent represents the send words.
Table 10-9 Overview of supported telegrams
Telegram Maximum number of PZD
1)
Received word Send word
Standard telegram1 2 2
Standard telegram2 4 4
Standard telegram3 5 9
Standard telegram5 9 9
Standard telegram7 2 2
Standard telegram9 10 5
Siemens telegram102 6 10
Siemens telegram105 10 10
Siemens telegram111 12 12
Siemens telegram 112 17 12
Siemens telegram750 (supplementary telegram) 3 1
1)
One PZD = one word
10.4.3
Telegrams for speed control
10.4.3.1 Telegram 1
Overview
The telegram is suitable for closed-loop speed control of a drive.
Functions
10.4Communication telegrams
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 333