User-de󹪝ned list
You com
pile the selected parameters in a user-de󹪝ned list. This involves an excerpt with
speci󹪝c parameters, from an underlying parameter list.
User-de󹪝ned lists are only created and edited in the project tree.
You use user-de󹪝ned lists for the following purposes:
Compiling the most important parameters
Assigning parameters to parameter groups with comments for users
Carrying out series commissioning based on saved parameter values
Documentation of the drive with listed parameters and setting values
Opening and reading parameter lists in the web server engineering tool
Parameter lists are exported in the json format. You can open lists and view parameter values
if you access the converter using the web server.
Example
In the following application, you create a user-de󹪝ned list with the objective of accepting
parameter values for an additional drive.
1. You create a user-de󹪝ned list with parameter values for a con󹪝gured drive.
2. You open the list in another drive with the same hardware con󹪝guration.
3. You compare the parameter values of the drive with the saved values.
4. You apply the required parameter values for the drive.
More information
For more information about parameter lists and use-de󹪝ned lists, see the related TIA Portal
information system.
Commissioning (Startdrive)
8.3Basics
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 229