Connection type Terminal type Conductor cross‑section Stripping length Cable lug
STO connection
2)
Spring-loaded 0.2mm² ... 1.5mm²
(A
WG: 24 … 16)
10mm Pin-type
Motor power connec‐
tion
Spring-loaded 0.75mm² ... 2.5mm²
(AWG: 18 …12)
9mm ... 10mm
Pin-type
Motor holding brake
2)
Spring-loaded 0.38mm² ... 0.75mm²
(AWG: 22 … 18)
9mm ... 10mm
Pin-type
1)
If you use cable lugs with insulat
ed end sleeves, make sure that the length of the cable lugs is 12 mm.
2)
For S200 PN only