Page #177 background image
Select "Con󹪝gure security settings"
De󹪝ne t
he settings for UMAC:
"Activate User Management & Access Control":
The function is activated by default.
If UMAC is activated, it can only be deactivated by a full reset of the converter to factory
settings. This causes all settings to be lost.
You can 󹪝nd more information about the full reset to factory settings in Section "Restore
factory settings (Page207)".
"Administrator setup":
Specify the user name and password of the drive administrator.
The drive administrator is permanently assigned the runtime role "Drive Administrator". This
assignment cannot be changed.
"Guest access con󹪝guration":
Specify whether the user has read rights without logging in and whether the user is allowed
to acknowledge results without logging in.
The option is deactivated in the factory setting. If guest access is not permitted, then the login
page is displayed when the web server is called.
De󹪝ne the settings to access the web server:
"Web server activation":
The factory setting to access the web server is service interface X127 with HTTPS protocol.
It is also possible to activate PROFINET interface X150 with HTTPS protocol.
If the factory settings are deactivated, then it is not possible to access the web server.
Assign an additional password for encryption of the drive data.
"Drive data encryption":
The function is activated by default.
The function encrypts sensitive data in the backup 󹪝le and on the memory card of the
converter. UMAC user data and passwords are sensitive data.
To use function "Drive data encryption" independent of UMAC, option "Activate UMAC for the
drive" must be deselected on page "Activate User Management & Access Control".
Check the con󹪝gured settings:
"Summary":
The summary provides an overview of the con󹪝gured settings.
Finish and continue
The settings are checked by clicking on "Finish". If there is no error, the settings are applied.
After 󹪝nishing, you can continue with one of the following options:
Continue with commissioning
Continue with the web server home page
More information
More information about "Drive data encryption" can be found on the Internet.
Commissioning (web server)
7.3Getting started
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 175

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals