WARNING
Spread of re fr
om built-in devices
Built-in devices can cause a re and a pressure wave in the event of a fault. Fire and smoke can
escape from the control cabinet and cause serious personal injury and property damage.
• Install built-in appliances in a robust metal control cabinet that is suitable for protecting
people from re and smoke.
• Only operate built-in devices with the control cabinet doors closed.
• Ensure that smoke can only escape via controlled and monitored paths.
WARNING
Active implant malfunctions due to electromagnetic elds
Con
ver
ters generate electromagnetic elds (EMF) in operation. Electromagnetic elds may
interfere with active implants, e.g. pacemakers. People with active implants in the immediate
vicinity of an converter are at risk.
• As the operator of an EMF-emitting installation, assess the individual risks of persons with
active implants.
• Observe the data on EMF emission provided in the product documentation.
WARNING
Active implant malfunctions due to permanent-magnet elds
Ev
en when
switched o, electric motors with permanent magnets represent a potential risk for
persons with heart pacemakers or implants if they are close to converters/motors.
• If you have a heart pacemaker or implant, maintain the minimum distance specied in the
Chapter "Technical data".
• When transporting or storing permanent-magnet motors always use the original packing
materials with the warning labels attached.
• Clearly mark the storage locations with the appropriate warning labels.
• IATA regulations must be observed when transported by air.
Fundamental safety instructions
2.1General safety instructions
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2