p0300[0] Motor type selection
Data type: Integer16 V
isible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Commissioning
Parameter group: Motor data, Quick commissioning
Unit: -
Min:
0
Max:
10000
Factory setting:
0
Description: Selects the motor type or start to read in the motor parameters for a motor with self-identifying data (p0300 = 10000).
For p0300 < 10000 the f
ollowing applies:
The 󹪝rst digit of the parameter value always de󹪝nes the general motor type and corresponds to the third-party motor
belonging to a motor list:
2 = rotating synchronous motor
Value: 0: No motor
2: Synchronous motor
2120: 1FL2 synchronous motor
10000: Motor with data set
Dependency: See also: p0301
p0301[0] Motor code number selection
Data type: U
nsigned32 V
isible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Commissioning
Parameter group: Motor data, Quick commissioning
Unit: -
Min:
0
Max:
99999999
Factory setting:
0
Description: Code number of the connected motor, whose data was accepted when commissioning.
Dependency: Code numbers are only possible for motor types that correspond to the motor type selected in p0300.
See also: p0300
Note
For a
motor with self-identifying data, p0301 cannot be changed. p0301 is automatically written to the code number
of the motor parameter read in (r0302) if p0300 is set to 10000. For other values, the commissioning routine cannot be
exited.
r0302[0] Motor code (identi󹪝ed)
Data type: Unsigned32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Motor data, Quick commissioning
Unit: -
Description: Displays the identi󹪝ed motor code number
.
When the drive powers up, the motor code is read out the motor. For r0302 = 0, the motor data were not identi󹪝ed.
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 711