p9829 SI reference checksum con󹪝guration of safe
ty functions chan. B
S200 PN Data type: Unsigned32 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tat
e:
Commissioning (Safety Integrated)
Parameter group: Extended functions
Unit: -
Min:
0000 he
x
Max:
FFFF FFFF hex
Fact
ory setting:
B2B2 B2B2 hex
Description: Sets the checksum over the checked parameters used to con󹪝gure safe
ty functions (reference checksum).
Dependency: See also: r9828
r9894 SI actual checksum safety enable channel B
S200 PN Data type: Unsigned32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group:
Unit: -
Description: Displays the checksum over the parameters to enable the safety functions (actual checksum) channel B.
Dependency: See also: p9895
p9895 SI reference checksum safety enable channel B
S200 PN Data type: Unsigned32 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tat
e:
Commissioning (Safety Integrated)
Parameter group:
Unit: -
Min:
0000 he
x
Max:
FFFF FFFF hex
Factory setting:
B2B2 B2B2 hex
Description: Sets the checksum over the parameters for enabling the safety functions (reference checksum) channel B.
Dependency: See also: r9894
r9898 SI actual checksum con󹪝guration of the dr
ive, channel B
S200 PN Data type: Unsigned32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Basic functions
Unit: -
Description: Displays the checksum over the checksum-checked parameters to con󹪝gure the dr
ive (actual checksum) channel B.
Dependency: See also: p9899