Note
To be observ
ed for devices used in Category C3
In a residential environment this product may cause radio-frequency interference.
• Do not use this device in the rst environment (residential area).
Note
Com
pl
ying wit
h Category C2 interference emission
When using a cable of more than 3 m to connect the converter to the PROFINET or Ethernet
interface, electromagnetic interferences may occur. Use appropriate ferrite clamps, cabinet
feedthrough, or ber optic transceivers to minimize the interference emission.
Note
The conducted and radiat
ed emissions of the PROFINET ports are in compliance with the
standards of IEC 61800‑6‑8, Class A (CISPR 32), and IEC 61800‑3 Category C3.
Application planning
4.8EMC-compliant installation
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 97