Appendix
A.8 Information List
SIPROTEC, 7UM62, Manual
C53000-G1176-C149-7, Release date 03.2010
595
147 Error Power Supply (Error Pwr-
Supply)
Supervision OUT ON
OFF
**LEDBO
160 Alarm Summary Event (Alarm
Sum Event)
Supervision OUT * * * LED BO 70 46 1 Yes
161 Failure: General Current Supervi-
sion (Fail I Superv.)
Measurem.Superv OUT on
off
**LEDBO70321Yes
164 Failure: General Voltage Supervi-
sion (Fail U Superv.)
Measurem.Superv OUT on
off
**LEDBO70331Yes
165 Failure: Voltage Summation
Phase-Earth (Fail Σ U Ph-E)
Measurem.Superv OUT on
off
* * LED BO 135 184 1 Yes
167 Failure: Voltage Balance (Fail U
balance)
Measurem.Superv OUT on
off
* * LED BO 135 186 1 Yes
171 Failure: Phase Sequence (Fail
Ph. Seq.)
Measurem.Superv OUT on
off
**LEDBO70351Yes
176 Failure: Phase Sequence Voltage
(Fail Ph. Seq. U)
Measurem.Superv OUT on
off
* * LED BO 135 192 1 Yes
177 Failure: Battery empty (Fail Bat-
tery)
Supervision OUT ON
OFF
**LEDBO
181 Error: A/D converter (Error A/D-
conv.)
Supervision OUT ON
OFF
**LEDBO
185 Error Board 3 (Error Board 3) Supervision OUT ON
OFF
187 Error Board 5 (Error Board 5) Supervision OUT ON
OFF
188 Error Board 6 (Error Board 6) Supervision OUT ON
OFF
190 Error Board 0 (Error Board 0) Supervision OUT ON
OFF
191 Error: Offset (Error Offset) Supervision OUT ON
OFF
**LEDBO
193 Alarm: NO calibration data avail-
able (Alarm NO calibr)
Supervision OUT ON
OFF
**LEDBO
194 Error: Neutral CT different from
MLFB (Error neutralCT)
Supervision OUT ON
OFF
**LEDBO
197 Measurement Supervision is
switched OFF (MeasSup OFF)
Measurem.Superv OUT on
off
* * LED BO 135 197 1 Yes
203 Waveform data deleted (Wave.
deleted)
Osc. Fault Rec. OUT_
Ev
ON * * LED BO 135 203 1 No
210 Err:1A/5Ajumper different from
settingS1 (Err1A/5AwrongS1)
Supervision OUT ON
OFF
**LEDBO
211 Err:1A/5Ajumper different from
settingS2 (Err1A/5AwrongS2)
Supervision OUT ON
OFF
**LEDBO
212 Err: TD1 jumper different from
setting (Err. TD1 jumper)
Supervision OUT ON
OFF
**LEDBO
213 Err: TD2 jumper different from
setting (Err. TD2 jumper)
Supervision OUT ON
OFF
**LEDBO
214 Err: TD3 jumper different from
setting (Err. TD3 jumper)
Supervision OUT ON
OFF
**LEDBO
230 Failure: Current Summation on
Side 1 (Fail. Σ I Side1)
Measurem.Superv OUT on
off
* * LED BO 135 155 1 Yes
231 Failure: Current Summation on
Side 2 (Fail. Σ I Side2)
Measurem.Superv OUT on
off
* * LED BO 135 158 1 Yes
264 Failure: RTD-Box 1 (Fail: RTD-
Box 1)
Supervision OUT ON
OFF
* * LED BO 135 208 1 Yes
265 Failure: Phase Sequence I side 1
(FailPh.Seq I S1)
Measurem.Superv OUT on
off
* * LED BO 135 156 1 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7UM62 and is the answer not in the manual?

Siemens SIPROTEC 7UM62 Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7UM62
CategoryProtection Device
LanguageEnglish

Related product manuals