P/N 79000035_SM, Version 1.5 6 - 17 Focus 30/35 Service Manual
Fig. 6-10 Check HA / VA collimation - CHz value out of tolerance, CV value in tolerance
7 Check HA/VA
collimation errors -
CV correction value is
out of tolerance and
CHz 30”.
A message box appears
and you have to answer
the question:
The vertical
collimation is out of
tolerance. Was the vertical
angle system
disassembled or partly
replaced?
Answering YES and go to
see “Adjustment of Reticle
F30 in Hz direction with
storing a new VA
correction” on page 6-28.
Condition:
CHz: 30” /
0,0083gon
CV: > 30” /
0,0083gon
A new VA
correction will
be stored in to
the MCB board
memory.
One component of the
angle system was
disassembled or
partly replaced.
Item Performance Description Result Notes