Event Code Message Text and Description Details and Solution
2. If the error persists, restore the
library configuration. See
Saving, Restoring, and
Resetting the Library
Configuration on pageî ±61.
2022
Drive has been hot removed
while in active status as LUN
master. Tape drives must be
powered off before removing
them from the library.
Reinsert the removed drive in the
same position from which it was
removed.
2023
Internal software error. Reboot the library.
2024
Exception thrown by
application not handled.
An unrecoverable error occurred.
Retry the operation and if the error
persists reboot the library.
2025
Move failure due to vertical
robotic assembly positioning
problem.
1. Check for obstructions, such as
a cartridge sticking out, in the
vertical pathway of the robotic
assembly.
2. Verify that the robotic
assembly is aligned and level
within the library.
3. Verify that the rack is level
front to back and side to side.
2026
Failed moving the robot
towards the back or front of
the library.
Check for obstructions, such as a
cartridge sticking out or cable
impeding progress, in the horizontal
pathway of the robotic assembly.
2027
Move failed pulling cartridge
from element.
Check for labels or cartridge
misalignments that would prevent
the cartridge from coming out of the
slot or drive.
2028
Move failed inserting
cartridge to element.
Check for labels or cartridge
misalignments that would prevent
the cartridge from being inserted into
the slot or drive.