Event Code Message Text and Description Details and Solution
2. Check the drive dump for
more information. See
Downloading Drive Logs on
page203.
4006
A drive temperature reported
is above the threshold.
1. Verify that the drive fan is
spinning and not obstructed.
2. Verify that the ambient
temperature is within
specification.
4007
Cartridge error. 1. Remove the cartridge and
inspect it for damage.
2. Retry the operation with
another cartridge.
4008
Cleaning tape expired. Discard the cleaning cartridge and
retry the cleaning operation with a
new cleaning cartridge.
4009
Firmware upgrade of one or
multiple expansion modules
failed.
The controller module must be able
to communicate with a powered on
and connected expansion module to
perform the upgrade.
1. Reseat the expansion module
controller.
2. Check the module interconnect
cable and power connections.
3. Retry the firmware upgrade.
4010
Drive is not compatible with
this library.
Remove the incompatible drive. Only
install drives that are supported by
the library.
4011
Drive is not supported in this
library.
4012
Move cartridge operation filed
due to drive issue.
1. Check events occurring at the
same time for drive problems.
JANUARY 2023 241
SPECTRA STACK LIBRARY
USER GUIDE
CHAPTER 9 - EVENT CODES