Event Code Message Text and Description Details and Solution
2. Retry the operation with the
same source and destination. If
the problem persists, retry the
operation with a different
cartridge in the same drive.
3. Check the drive dump for
more information. See
Downloading Drive Logs on
page203.
4013
Exchange cartridge failed due
to a drive issue.
1. Retry the operation with the
same source and destination. If
the problem persists, retry the
operation with a different
cartridge in the same drive.
2. Check the library event log for
events associated with this
drive. See Viewing Log Files
on page195.
3. Check the drive dump for
more information. See
Downloading Drive Logs on
page203.
4014
Library test failed due to a
drive issue.
1. Verify the test parameters and
then retry the test.
2. Check the library event log for
events associated with this
drive. See Viewing Log Files
on page195.
3. Check the drive dump for
more information. See
Downloading Drive Logs on
page203.
4015
Power supply has failed.
Redundancy is not available.
1. Ensure that all power supplies
are installed properly.
JANUARY 2023 242
SPECTRA STACK LIBRARY
USER GUIDE
CHAPTER 9 - EVENT CODES