Event Code Message Text and Description Details and Solution
2. Verify that all power sources
are supplying power that is
within the product
requirements.
4016
Backup configuration data to
controller module failed.
1. If possible, save the library
configuration to a file.
2. Power cycle the library and
retry the operation.
4017
Restore configuration data
from chassis failed.
4018
Firmware upgrade of one or
more drives failed due to drive
issue.
1. Verify that the firmware file is
correct for the drive.
2. Ensure that the drive is in a
healthy state and does not
have a cartridge loaded.
3. Retry the operation.
4019
General drive firmware bundle
upgrade failure.
4020
Database has been reset due to
a problem that prevented the
library from powering up.
Restore previously saved
configuration data.
4021
Drive has been hot removed
while in active status as data
transfer device. Drives must be
powered off before removing
them from the library.
Reinsert the removed drive in the
same position from which it was
removed.
4022
A full-height drive in incorrect
boundary location. Full-height
drives only operate in the very
top, very bottom, or middle
pair of half-height drive bays.
Reinstall the tape drive in an
acceptable location.
4023
Drive not cable (ports not
linked up).
The tape drive must have an FC or
SAS cable attached to transfer data
and communicate with host
applications.
4024
One or two unit position
transmitter/detector failures.
Contact Spectra Logic Technical
Support. See Contacting Spectra
Logic on page11.
JANUARY 2023 243
SPECTRA STACK LIBRARY
USER GUIDE
CHAPTER 9 - EVENT CODES