9. Click Next. If you have enabled EE ports (see Enabling or Disabling EE Ports on
page83), the Assign EE Ports screen displays.
Figure37 The Assign EE Ports screen.
In the Assign EE Ports screen, use the >> and << buttons to assign EE ports to the new
partition. EE Port locations are shown in the format
module.slot-module.slot where:
module - The module number. Modules are numbered based on their location in
the physical library. The bottom module is Module 1.
slot - The slot number as shown in Figure6 on page39.
Note: The EE port can be shared by partitions, but individual slots cannot. Importing or
exporting cartridges in a partition without assigned EE slots requires magazine
access, which takes all partitions in the library offline. EE port access does not take
partitions offline.