Field Setting
Security Configuration - Administrator Authentication
Current password Enter the current password.
New username Enter a new username.
New password (Optional) Enter a new password.
New password again
(Optional)
Enter the new password again to confirm.
Strict password requirements
(Optional)
If enabling strict password requirements, the device can be con-
figured to enforce certain security rules and naming con-
ventions. For more information, see "Parameter Overview" on
page223.
Note: Once enabled, this setting can only be disabled by a fact-
ory reset (Configuration > Factory Reset) that will remove all
configuration and user data.
Password expiration (Optional) Select when you want the password to expire.
Possible values: Never, 30 days or 90 days.
Default value: Never
Note: Once enabled, this setting can only be disabled by a fact-
ory reset (Configuration > Factory Reset) that will remove all
configuration and user data.
Security Configuration - Data protection
Allow unencrypted HTTP
(Optional)
HTTPS is forced by default.
If enabled, HTTP support is supported instead of HTTPS.
Note: Enabling unencrypted HTTP can cause passwords and
other sensitive data to be transmitted in clear text on the net-
work.
Allow remote logging
(Optional)
If enabled, remote logging is allowed.
Remote logging allows for Spectralink debug tools to extract
debug information from the unit.