14215700-IG, Edition 8.0
April 2018, Original document
74
Numbering of Base Stations/Server 200/400 and Repeaters in a Normal Con-
figuration
Note:
Repeater and base station/server RPNs must not be the same. Also, in a situation
where common overlap is present between the actual units, a repeater cannot have an
RPN that is similar to that of a base station/server or another repeater. If this occurs, han-
dover between the different units is not possible.
First Repeater
l RPN of base station/server 200/400 + 64
l Base to synchronize on: RPN of base station/server
Second Repeater
l RPN of base station/server 200/400 + 128
l Base to synchronize on: RPN of base station/server
Third Repeater
l RPN of base station/server 200/400 + 192
l Base to synchronize on: RPN of base station/server
Below is an example of base station and repeater numbering in a normal configuration.