244
Field Setting
Redundancy Configuration - Settings
Failover time(sec) Enter value for failover time.
Failure time is the time in seconds from the Spectralink IP-
DECT Server detects a failure, until it initiates a failover oper-
ation and cause the other peer to take over.
Default value: 15 sec
For more information about failure time, see "Failover time con-
ditions" on page192.
Configuration - Provisioning
Field Setting
Provisioning Configuration - Server
Method The Spectralink IP-DECT/DECT Server must know the pro-
tocol and address of server containing the firmware and con-
figuration.
The Spectralink IP-DECT/DECT Server can use the fol-
lowing methods to obtain the provisioning server URL:
l Disabled (The Spectralink IP-DECT/DECT Server
will not use provisioning)
l Static (The administrator must manually specify the
URL of the provisioning server)
l DHCP (Option 66)
Select the relevant method for obtaining the URL of the pro-
visioning server.
Default value: DHCP