245
Field Setting
URL If using Static for obtaining the URL of the provisioning
server, enter an URL.
Accepted format of URL is: [<protocol>://[<user-
name>:<password>@]]<host>[:<port>][/<path>]
Examples:
l 10.0.0.10
l tftp://provisioning.test.com
l ftp://192.168.0.1
l ftp://user:password@provisioning.example.com
l http://server.example.com/boot.
l https://server.example.com:10443/boot
For more information about protocols and , see "Protocol" on
page1.
Provisioning Configuration - Checking
Interval(minutes) The interval between polling the provisioning server. If the
value is set to 0, then periodic polling is disabled.
Enter a value if you want to use polling for checking updates
automatically.
Time(hh:mm) Enter a value to poll the provisioning server at a specific time
each day.
Leave it empty if not using polling.
NOTIFY check_sync Possible values: Disabled, Update or Reboot.
If disabled is selected, polling (defining specific time/interval
for automatic check for new updates) is used.
If Update is selected, then SIP Notify Check-Sync is used for
automatic notification of new updates. Using this method is
the optimum way to handle updates.
Default value: Disabled
For more information about polling, SIP Notification Check-
Sync method and "check-sync" events, see "Automatic
Check for New Firmware and Configuration" on page1.
Provisioning Configuration - Configuration
Import Enable.
If enabled, this will make automatic update possible if a
default firmware file is available.