14215700-IG, Edition 8.0
April 2018, Original document
75
Numbering of Repeaters in a Repeater Daisy Chain Configuration
First Repeater in Chain
l RPN of base station/server 200/400 + 64
l Base to synchronize on: RPN of base station/server
Second Repeater in Chain
l RPN of base station/server 200/400 + 128
l Base to synchronize on: RPN of previous repeater
Third Repeater in Chain
l RPN base station/server 200/400 + 192
l Base to synchronize on: RPN of previous repeater
Below is an example of repeater numbering in a daisy chain configuration.
Spectralink IP-DECT Server 200/400/6500 Installation and Configuration Guide